Food, Beverage and Dairy
Food, Beverage and Dairy

NVS Point level sensor with thread M12 (CLEANadapt)

Point Level Sensors

Types: NVS-041
Conductive limit detection in metallic vessels/pipes with hygienic thread M12 (CLEANadapt)

  • Reliable full / empty detection of aqueous and conductive media in metallic pipes and vessels
  • Individual shortening and twisting of the rod possible
  • Single rod sensor with intergrated electronics
  • Installation in pipes from DN15 on
  • Sensor head 55mm
  • Please note that the types NVS-043 / NVS-046 are discontinued

Technical Specification

Process Connection CLEANadapt G1/2" | Adapter for Tri-Clamp, Varivent, APV, Dairy flange
Insertion length 9 mm
Wetted material Stainless steel 1.4404 (316L) Ra≤0.8 μm | PEEK
Measuring range Minimum conductivity 1 μS/cm
Available versions Electrode blank | coated
Temperature range process 0…140 °C
Temperature range CIP/SIP 143 °C / max. 120 min.
Operating pressure max. 10 bar
Communication PNP
The values shown are the performance limits within the product line. The product-specific data for each individual configuration can be obtained from the product information

Application

Download

Process Connection

Configuration and 3D Data